ITCertKing is website that can help a lot of IT people realize their dreams. If you have a IT dream, then quickly click the click of ITCertKing. It has the best training materials, which is ITCertKing;s HP HP0-S17 exam training materials. This training materials is what IT people are very wanted. Because it will make you pass the exam easily, since then rise higher and higher on your career path.
ITCertKing is a convenient website to provide training resources for IT professionals to participate in the certification exam. ITCertKing have different training methods and training courses for different candidates. With these ITCertKing's targeted training, the candidates can pass the exam much easier. A lot of people who participate in the IT professional certification exam was to use ITCertKing's practice questions and answers to pass the exam, so ITCertKing got a high reputation in the IT industry.
Many candidates who are ready to participate in the HP certification HP0-S17 exam may see many websites available online to provide resources about HP certification HP0-S17 exam. However, ITCertKing is the only website whose exam practice questions and answers are developed by a study of the leading IT experts's reference materials. The information of ITCertKing can ensure you pass your first time to participate in the HP certification HP0-S17 exam.
There are many ways to help you prepare for your HP HP0-S17 exam. ITCertKing provide a reliable training tools to help you prepare for your HP HP0-S17 exam certification. The ITCertKing HP HP0-S17 exam materials are including test questions and answers. Our materials are very good sofeware that through the practice test. Our materials will meet all of theIT certifications.
Exam Code: HP0-S17
Exam Name: HP (Integrating and Managing HP BladeSystem in the Enterprise)
One year free update, No help, Full refund!
Total Q&A: 130 Questions and Answers
Last Update: 2013-10-09
Do you want to pass the HP HP0-S17 exam better and faster? Then please select the ITCertKing. It can help you achieve your dreams. ITCertKing is a website that provide accurate exam materials for people who want to participate in the IT certification. ITCertKing can help a lot of IT professionals to enhance their career blueprint. Our strength will make you incredible. You can try a part of the questions and answers about HP HP0-S17 exam to test our reliability.
There a galaxy of talents in the 21st century, but professional IT talents not so many. Society need a large number of professional IT talents. Now IT certification exam is one of the methods to inspect the employees' ability, but it is not so easy to is one of the way to IT certification exams. Generally, people who participate in the IT certification exam should choose a specific training course, and so choosing a good training course is the guarantee of success. ITCertKing's training course has a high quality, which its practice questions have 95% similarity with real examination. If you use ITCertKing's product to do some simulation test, you can 100% pass your first time to attend IT certification exam.
ITCertKing is a website that provide the counseling courses for IT professionals to participate in HP certification HP0-S17 exam and help them get the HP HP0-S17 certification. The courses of ITCertKing is developed by experienced experts' extensive experience and expertise and the quality is very good and have a very fast update rate. Besides, exercises we provide are very close to the real exam questions, almost the same. When you select ITCertKing, you are sure to 100% pass your first time to participate in the difficult and critical HP certification HP0-S17 exam.
HP0-S17 Free Demo Download: http://www.itcertking.com/HP0-S17_exam.html
NO.1 A customer has a Virtual Connect managed enclosure and needs to move one of the blades to a
non-virtual connect enclosure.
What should be done so that duplicate MAC addresses and WWNs do not appear in the datacenter due
to server blade deployment?
A.Enable the Reset to factory default switch on the blade system board.
B.Run the erase utility on the blade before plugging the server to the network.
C.First delete all MAC and WWNs configurations while the server is in the VC managed enclosure and
then move the server to the non-VC managed enclosure.
D.MAC addresses and WWNs are automatically returned to factory defaults when the server is moved to
the non-Virtual connect enclosure so no duplicate MAC addresses or WWNs appear.
ANSWER: D
HP HP0-S17 HP0-S17 HP0-S17 HP0-S17 HP0-S17 exam prep
NO.2 Which devices can be assigned an IP address through Enclosure Bay IP Addressing (EBIPA) for
c-Class server blades? (Select two.)
A.iLO 2 cards
B.interconnects
C.Insight Display
D.LAN interfaces of mezzanine cards
E.iSCSI target IP address on server blades
ANSWER: AB
HP HP0-S17 pdf HP0-S17 HP0-S17 exam simulations HP0-S17
NO.3 After replacing a failed drive in a server blade, your customer complains about long logical drive time
recovery. What can you do to reduce recovery time?
A.Migrate the logical drive to RAID 6.
B.Install MPIO software on the server blade.
C.Set the rebuild priority to high on the controller.
D.Enable the Tagged Command Queuing (TCQ) feature on the hard drive.
ANSWER: C
HP original questions HP0-S17 exam simulations HP0-S17 HP0-S17 test HP0-S17
NO.4 Which interconnect module offered by HP has the capability of assigning a configuration profile to a
specific server blade?
A.GbE2c Switch
B.Cisco 3020 Switch
C.Virtual Connect Ethernet
D.Ethernet Pass-Thru Module
ANSWER: C
HP pdf HP0-S17 test questions HP0-S17 HP0-S17 certification HP0-S17 test questions HP0-S17
NO.5 A customer that usually works with a c3000 Enclosure needs to use the external DVD drive on a
c7000 Enclosure and connect the drive to all servers in the c7000 Enclosure.
How can the external DVD drive on the c7000 Enclosure be accessed?
A.Use the DVD drive integrated in the c7000 Enclosure.
B.Use the DVD drive connected to the downlink port of the c7000 Enclosure.
C.Use the DVD drive connected to the USB port on an Onboard Administrator module.
D.Use the DVD drive attached through the serial/USB/video cable attached to any server blade.
ANSWER: C
HP exam HP0-S17 demo HP0-S17 HP0-S17 questions
NO.6 The Virtual Connect Fibre Channel module uses which type of Port ID Virtualization protocol to
aggregate multiple Fibre Channel HBAs over a smaller number of physical uplinks?
A.E_Port
B.F_Port
C.L_Port
D.N_Port
ANSWER: D
HP HP0-S17 exam HP0-S17 HP0-S17 exam simulations HP0-S17 practice test
NO.7 A customer is looking for a virtualization solution for their data center. Their main area of concern is
server down time.
You have identified the x86-based virtualization candidates. Which platform best suits the customer's
needs?
A.scale-up
B.scale-out
C.Integrity VSE
D.single server virtual consolidation
ANSWER: B
HP test questions HP0-S17 HP0-S17 HP0-S17 HP0-S17 dumps HP0-S17
NO.8 An administrator needs to monitor performance of every drive connected to the Smart Array controller.
Each drive is configured as a single logical drive.
Which tool can be used?
A.Insight Diagnostic
B.Radia Performance Manager
C.Performance Management Pack
D.Windows Server Performance Monitor
ANSWER: C
HP HP0-S17 exam HP0-S17
NO.9 An administrator configures an HP c7000 Enclosure using Onboard Administrator. Which option can
be used to automatically configure IP addresses for all iLO cards and interconnect modules?
A.Insight Display
B.Virtual Connect Manager
C.Interconnect LAN Manager
D.Enclosure Bay IP Addressing (EBIPA)
ANSWER: D
HP HP0-S17 original questions HP0-S17 questions
NO.10 Your customer has a c7000 Enclosure and two power supplies installed in bays 1 and 2. They are
switching from single-phase power to a three-phase power subsystem with full redundancy.
Which action is necessary to make this configuration work and be supported?
A.Install 4 additional power supplies.
B.Move the power supplies to bays 1 and 4.
C.Turn off the Dynamic Power Saver feature.
D.Enable three-phase power using the Onboard Administrator.
ANSWER: A
HP answers real questions HP0-S17 HP0-S17 HP0-S17 HP0-S17 dumps
NO.11 Which industry standard memory technologies are supported in a BL465c Server Blade? (Select two.)
A.memory sparing
B.memory mirroring
C.memory interleaving
D.ECC and Advanced ECC
E.833MHz maximum speed DIMMs
ANSWER: CD
HP HP0-S17 exam HP0-S17 HP0-S17 certification training
NO.12 Which features does Virtual Connect Ethernet module (VC-Enet) provide in a network environment?
(Select two.)
A.VC-Enet can stack across four enclosures in a rack.
B.VC-Enet appears as an HP ProCurve device to other network devices.
C.VC-Enet will not add any new switches for the network administrator to manage.
D.VC-Enet domains can be created directly using the Onboard Administrator console.
ANSWER: AC
HP braindump HP0-S17 exam HP0-S17
NO.13 Which interconnect option creates domains and stacks LAN modules across c7000 Enclosures?
A.GbE2c Ethernet
B.Virtual Connect Ethernet
C.Ethernet Pass-Thru Module
D.Virtual Connect Fibre Channel
ANSWER: B
HP HP0-S17 exam dumps HP0-S17 questions HP0-S17
NO.14 Which ProLiant Essentials Value Pack is an integrated power monitoring and management
application that provides centralized monitoring and control of datacenter power consumption and thermal
output?
A.Insight Power Manager
B.HP Rack and Power Manager
C.Performance Management Pack
D.Vulnerability and Patch Management Pack
ANSWER: A
HP HP0-S17 HP0-S17 HP0-S17
NO.15 What is the purpose of the HP StorageWorks SB40c Storage Blade?
A.provides a blade form factor tape solution for any server supporting the TCP/IP protocol
B.provides a blade form factor networked shared storage for any server supporting IP-based storage
(iSCSI)
C.provides additional storage capabilities dedicated to a single server blade within the same c7000
Enclosure
D.provides additional storage capabilities dedicated to a single server blade in another linked c7000
Enclosure
ANSWER: C
HP HP0-S17 questions HP0-S17 test
NO.16 Your customer wants to replace an existing c3000 Enclosure with a c7000 Enclosure. Which
components from the c3000 Enclosure can be reused in the c7000 Enclosure? (Select three.)
A.fans
B.power supplies
C.interconnect modules
D.server and storage blades
E.Onboard Administrator module
ANSWER: ACD
HP study guide HP0-S17 study guide HP0-S17 HP0-S17 HP0-S17
NO.17 Which industry standard protocols are used by HP SIM? (Select two.)
A.XML
B.TFTP
C.iSCSI
D.WBEM
E.NetBEUI
ANSWER: AD
HP HP0-S17 answers real questions HP0-S17 HP0-S17 HP0-S17 test
NO.18 Which tool tests and evaluates the hardware and software configuration of systems where HP SIM is
installed or is being considered for installation?
A.Insight Control Advisor
B.HP SIM Capacity Planner
C.Active Answers Solution Sizer
D.Site Installation Preparation Utility
ANSWER: A
HP exam prep HP0-S17 certification training HP0-S17 HP0-S17
NO.19 You are administrating several c-Class enclosures and are looking for a unified authentication system
for all iLO cards and Onboard Administrator modules.
What is the proper solution?
A.HP Protect Tools
B.Credential Manager
C.Virtual Connect Enterprise Manager
D.Lightweight Directory Access Protocol (LDAP)
ANSWER: D
HP HP0-S17 braindump HP0-S17 HP0-S17 answers real questions
NO.20 A customer wants to deploy a c7000 Enclosure and six server blades in a datacenter with limited
power. How can they ensure the solution fits within the available datacenter power envelope?
A.The customer needs to make sure they have at least 6750 watts of available power in every case.
B.Use the HP BladeSystem Sizer to determine how much power is needed for the configuration they want
to deploy.
C.Use the HP Rack and Power tool to determine how much power is needed for the configuration they
want to deploy.
D.Use the Enterprise Configurator in ActiveAnswers to determine how much power is needed for the
configuration they want to deploy.
ANSWER: B
HP HP0-S17 HP0-S17 dumps
NO.21 Your customer is looking for an Ethernet interconnect with Fibre uplinks for their c7000 Enclosure.
Which interconnects should be considered? (Select two.)
A.GbE2c Switch
B.Infiniband switch
C.Cisco Catalyst 3020
D.GbE2c Layer 2/3 Switch
E.Ethernet Pass-Thru Module
ANSWER: CD
HP HP0-S17 test questions HP0-S17 questions
NO.22 Which industry standard processor options are supported in the HP BL460c Server Blade? (Select two.)
A.Dual-Core Intel Xeon
B.Quad-Core Intel Xeon
C.Dual-Core Intel Itanium2
D.Dual-Core AMD Opteron
E.Quad-Core AMD Opteron
ANSWER: AB
HP exam prep HP0-S17 test HP0-S17 HP0-S17 HP0-S17 certification training HP0-S17 test questions
NO.23 What is an advantage of a c7000 Enclosure compared to a c3000 Enclosure in an enterprise
environment?
A.N+N redundancy in the power subsystem
B.Virtual Connect and storage blade support
C.interconnect redundancy for integrated NICs
D.application of Onboard Administrator advanced license
ANSWER: C
HP HP0-S17 HP0-S17 demo
NO.24 A BladeSystem enclosure is managed by one Onboard Administrator that failed. Which functionality is
still available? (Select two.)
A.iLO 2 is accessible.
B.All fans are up and running.
C.Server blades can access the SAN.
D.New server blades can be added and powered up.
E.New interconnect devices can be added and powered up.
ANSWER: BC
HP answers real questions HP0-S17 exam simulations HP0-S17 practice test HP0-S17 demo HP0-S17 braindump
NO.25 Which service features are included in the Enhanced Network Installation and Startup Service for
BladeSystem Switches? (Select two.)
A.service planning interview
B.network device configuration
C.comprehensive porting and migration
D.systematic analysis of configurations for software patch version inconsistencies
E.proactive and rapid-response services to protect strategic operations against downtime risks
ANSWER: AB
HP practice test HP0-S17 HP0-S17
NO.26 Which industry standard memory technology can be used by Intel Xeon-based c-Class server blades
to provide additional protection against failed or degrading FB-DIMMs? (Select two.)
A.Advanced ECC
B.mirrored memory
C.registered DIMMs
D.online spare memory
E.interleaved memory support
ANSWER: BD
HP HP0-S17 HP0-S17 dumps
NO.27 Which industry standard technologies are compatible with the SB600c AiO Storage Blade? (Select
two.)
A.ATA
B.SAS
C.SCSI
D.iSCSI
E.SATA
ANSWER: BD
HP HP0-S17 HP0-S17 HP0-S17
NO.28 Which service features are included in the Enhanced Network Installation and Startup Service for
BladeSystem Switches? (Select two.)
A.verification of operation
B.confirmation of software revisions
C.comprehensive porting and migration
D.systematic analysis of configurations for software patch version inconsistencies
E.proactive and rapid-response services to protect strategic operations against downtime risks
ANSWER: AB
HP HP0-S17 exam HP0-S17 HP0-S17 HP0-S17 test answers
NO.29 You are replacing one of your redundant GbE2c interconnect switch modules in your c7000 Enclosure.
What must you be aware of when you install a replacement GbE2C switch with default settings into the
enclosure?
A.Crosslink ports are disabled and redundancy is lost between switches.
B.Crosslink ports are enabled and will cause a loop in your switch topology.
C.Uplink ports are disabled and must be enabled manually in the switch manager.
D.Downlink ports are disabled and must be enabled manually in the switch manager.
ANSWER: A
HP certification HP0-S17 HP0-S17 HP0-S17
NO.30 Which management suite delivers core management functionality for the HP BladeSystem solution,
including server deployment, health monitoring, performance monitoring, vulnerability scanning and patch
management?
A.HP Storage Essentials
B.HP Operations Software
C.Insight Control Environment
D.HP Systems Insight Manager
ANSWER: C
HP HP0-S17 original questions HP0-S17 HP0-S17 HP0-S17 HP0-S17 original questions
ITCertKing offer the latest 000-123 exam material and high-quality 00M-620 pdf questions & answers. Our HP2-B101 VCE testing engine and VCP-510 study guide can help you pass the real exam. High-quality 000-283 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertking.com/HP0-S17_exam.html
没有评论:
发表评论